Get a quote

5Ton Rice Husk Boiler

  • Steam Boiler - Combo Multi Fuel Fired Steam Boiler

    Manufacturer of Steam Boiler - Combo Multi Fuel Fired Steam Boiler, Solid Fuel Fired Twin Furnace Steam Boiler, Multi Fuel Fired Steam Boiler and MSF IBR Steam Boiler offered by Maxtherm (India) Private Limited, Chennai, Tamil Nadu. · 3 Pass Fully Wet Back Design · Capacity -1.0 Ton /Hr to 60 Tons /Hr · Maximum Operating Pressure 10.54 Learn More

  • Know the Basics of Fire-Tube Steam Boilers - Teems Electric

    Three Pass Fully Wet Back Boiler. Wetback design: 3 pass, conventional, wet back, integral furnace without refractory reduces maintenance costs and increases boiler efficiency. Triple grate bar block in furnace: Reliable, strong, sturdy and easy to maintain triple grate bar improves overall performance of boiler. Higher combustion efficiency: Large furnace volume increases …Learn More

  • Firetube Boilers - National Board of Boiler and Pressure

    The top tube sheet in a steam boiler can be above or below the water line. When it is above, it is called a dry-top and when it is below, it is called a wet-top. A vertical boiler has a small "footprint" and can be installed in boiler rooms with limited space. Vertical boilers are very popular in the dry cleaning industry.Learn More

  • Steam Boiler - 10 TPH Gas Fired Wet Back Design Boiler

    Manufacturer of Steam Boiler - 10 TPH Gas Fired Wet Back Design Boiler, Solid Fuel Fired Fluidized Bed Combustion IBR Steam Boiler, Oil And Gas Waste Heat Recovery Boiler and Industrial Water Wall Steam Boiler offered by Urjex Boilers Private Limited, Meerut, Uttar Pradesh.Learn More

  • CLASSIC 3-PASS WET BACK PACKAGE FIRE TUBE BOILER

    The Enertech Classic 3-Pass Wet Back Package Fire Tube Boiler is a high performance boiler unit with design parameters based on the generously built top of the line US boilers, suitable for firing bunker C oil, Diesel oil, LPG or Natural Gas. It is available in capacities from 60 to 1500 boiler horsepower (940 to 23,500 kg/h), with operating pressures of up to 270 psig (18.63 Bars).Learn More

  • Hurst Series 500 - Steam Boiler | Prime Boiler Services

    The Hurst 500 Series four-pass wetback scotch marine boiler is an ideal choice for all commercial and industrial applications when engineering mechanical systems using the latest HVACR technologies. The Hurst 500 Series boiler provides fuel efficiencies that exceed most four-pass designs. Having no large refractory rear door, these boilers Learn More

  • Boiler Brand 20 Ton Distributor Turkmenistan

    Steam Boiler - Wet Back Design Gas Fired Boiler. Steam Offering you a complete choice of products which include wet back design gas fired agro waste fired steam three pass steam fully automatic steam urjex make hsd oil fired steam and fluidized bed combustion. Get A Quote.Learn More

  • Scotch Marine Boiler | Three Pass Wetback | Series 400

    With computer aided design, Hurst has made the wet back a space saving workhorse without sacrificing the principle of 5 sq. ft. of heating surface per BHP. Combustion Hurst uses name brand burner components with proven reliability. Every unit is boiler/burner compatible and tested at the factory prior to shipment. Standard Steam TrimLearn More

  • THREE PASS WET BACK REVERSE FLAME

    Boilers rated above 2000 kg/hr F & A 100°C are of fully wet-back design. The furnace tube is designed to allow adequate expansion and is located between the front tube plate and the totally submerged reversal chamber. The rear reversal chamber plate is stayed to the Boiler rear tube plate with the required number of stay bars.Learn More

  • 4 Different Designs of the Fire Tube Boiler: Which Is Best

    Steam Boiler Wet Back Design Gas Fired Boiler 2200kg hr Natural gas steam boiler. GET A QUOTE. Name: Email: Ton: Phone: Company: Select: Please tell us the type of boiler you need. Steam Boiler. Hot Water Boiler. Please tell us the boiler fuel you will use. Gas. Oil. Biomass. Other Learn More

  • Steam Boiler Wet Back Design Gas Fired Boiler 2200kg hr

    The wetback boiler design features a reversal chamber that is jacketed, or completely surrounded by water, which is used to direct flue gasses from the furnace to the tube banks. The surrounding water absorbs burner heat, helping improve operating efficiency as heat from combustion goes directly into evenly heating water instead of refractory.Learn More

  • Steam Accumulators and Steam Boiler Response to Load …

    boiler, design in back pressure regulators to control depressurization or use a steam accumulator. steam boiler system servicing the autoclave without an accumulator. According to the graph, if then a wet accumulator can be used. A wet accumulator is a pressurized vessel in line with the boilerLearn More

  • FWB SERIES – INDUSTRIAL FULLY WET BACK MODELS

    A three-pass, fully wet back steam boiler. A single block unit, features excellent efficiency and offers high-level and versatile technical solutions as tested and applicable to varying industries in the kingdom. It is designed and built to ensure maximum …Learn More

  • Design of Boilers (With Diagram) | Thermodynamics

    Design of Cochran Boiler: It is a Fire tube, Stationary, Multi-tubular, Internally fired, vertical boiler. Cochran boiler is made in many sizes capable of producing steam upto 3 T/hour and working pressures upto 17 bar. This boiler gives Thermal efficiency (ƞ th) of 70% with coal firing and about 75% with oil firing.Learn More

  • Steam Boiler - Wood Fired 1000 kg/hr Package Steam Boiler

    A three-pass, fully wet back steam boiler. A single block unit, features excellent efficiency and offers high-level and versatile technical solutions as tested and applicable to varying industries in the kingdom. It is designed and built to ensure maximum …Learn More

  • THREE PASS WET BACK REVERSE FLAME

    Design All boilers in the range are of fully wet-back design. The furnace tube is designed to allow adequate expansion and is located between the front tube plate and the totally submerged reversal chamber. The rear reversal chamber plate is stayed to the Boiler rear tube plate with the required number of stay bars.Learn More

  • Boiler – Fundamentals and Best Practices

    Dry back or wet back design Single fuel or dual fuel design Little or no steam separation equipment. Fire Tube Boilers. Fire Tube Boilers. Typical designs are O, D and A type boilers Steam separation equipment - drum furniture Cyclone separators Demister pads Baffle plates Have economisers and superheatersLearn More

  • What is a wet back boiler? What are the cleaning methods

    Mar 17, 2021 · The above introduced the cleaning methods of wet-back boilers and wet-back steam boilers. When using industrial boilers, pay attention to adopting scientific and reasonable operation methods, and regularly maintain the boilers and test the water quality to ensure the boiler's operating effect and service life.Learn More

  • THREE PASS WET BACK REVERSE FLAME

    Boilers rated above 2000 kg/hr F & A 100°C are of fully wet-back design. The furnace tube is designed to allow adequate expansion and is located between the front tube plate and the totally submerged reversal chamber. The rear reversal chamber plate is stayed to the Boiler rear tube plate with the required number of stay bars.Learn More

  • Raz Boilers | Steam Boilers

    Solid Fuel Fired (IBR) Steam Boilers. Capacity: 300 kgs/hr and above. Type: horizontal, shell type smoke tube boiler. Fully automatic, three pass wet back design. High efficiency 75±2 [NCV]. Fitted with all safety and indigenies accessories. Can be designed to …Learn More

Provide you with the most suitable plan and price

Start your project